Positioning Parameter

 

The following positioning parameters can be configured by using Positioning for PLC-S Special Program in CICON. The configured parameters are saved in the same area (flash memory) as that of sequence program and therefore will be preserved even after power is lost.

 

Offset

Item

Configuration Details

R/W

Remark

Default

Function

0

Select Pulse Output

0

0=Not Used

1=High Active

2=Low Active

W

 

1

Bias Speed

1

1 ~ 100,000 PPS

DW

Low

2

High

3

Speed Limit

50,000

Low

4

High

5

Acceleration/Dec Time 1

1,000

1 ~ 65,535 mSec

W

 

6

Acceleration/Dec Time 2

 

7

Acceleration/Dec Time 3

 

8

Acceleration/Dec Time 4

 

9

S/W Upper Limit

2,147,483,647

-2,147,483,648 ~ 2,147,483,647

DW

Low

10

High

11

S/W Lower Limit

-2,147,483,648

Low

12

High

13

Position address under speed control

0

0=Do not update

1=Update

2=Clear and update

W

 

14

Backlash Compensation

0

0 ~ 65,535 Pulse

W

 

15

Ext. Upper/Lower Limit Signal

0

0=Not Used, 1=Wired (Used)

W

 

16

Jog Speed Limit

20,000

1 ~ 100,000 PPS

(Bias Speed<Jog Speed<Speed Limit)

DW

Low

17

High

18

Jog Acceleration/Dec Time

0

Number of Acc/Dec Time (0~3)

W

 

19

Inching Speed

100

0 ~ 65,535 PPS

W

 

20

Complete Output Signal Duration

1000

0 ~ 65,535 mSec

W

 

21

OPR Method

0

0=DOG / Zero OFF

1=DOG / Zero ON

2=DOG

W

 

22

OPR Direction

0

0=Forward, 1=Backward

W

 

23

Origin Address

0

-2,147,483,648 ~ 2,147,483,647

DW

Low

24

High

25

OPR High Speed

50,000

1 ~ 100,000 PPS

DW

Low

26

High

27

OPR Low Speed

1,000

1 ~ 100,000 PPS

DW

Low

28

High

29

OPR Acceleration/Dec Time

0

Number of Acc/Dec Time (0~3)

W

 

30

DWELL Time

0

0 ~ 50,000 mSec.

W