Error Codes (Address "19")

Buffer Memory Address "19"

The error codes detected from an A/D module are stored in these addresses.
is from 1 to 4 for AD04VI and from 1 to 8 for AD08I and AD08V(The number means the channel.) is from 1 to 3.
If an error occurs, it will be kept till it is cleared or the power is off. If an error is not cleared after it occurs, an newly occurring error will be disregarded. (To clear an error, use the CICON to set or reset the YOF (Requesting to clear error).)

[ Error codes are decimal figure.]

 

Error code

Description

1

The case that the range of input setup is wrong

The case that current is set up in AD08V or voltage is set up in AD08I

2

The case that average process time is out of range

3

The case that number of average process times is out of range

4

The case that an offset value is greater than a gain value

49

The case that offset channels and gain channels are calibrated at the same time

10image-20240325-040426.png

Error in system (A/S required)