Output Signals - D/A Converters
Device NO. | Name of Signal | Description |
Y0A | Requesting to set up operation condition | This is set when the contents of enabling/disabling to D/A- convert, hold/clear are effective. Refer to X0A(Flag indicating operation set up) for set/reset timing. |
Y0B | Requesting to switch an channel | This is set when the channel for offset/gain calibration is changed. Refer to X0B(Flag indicating channel switched) for set/reset timing |
Y0C | Requesting to modify an set value | This is set and reset if an analog output value is increased or decreased when offset/gain are calibrated. According to the value set up to Buffer Memory Address 21, analog output is increased or decreased. |
Y0D | Requesting to calibrate offset or gain | This is used to calibrate offset/gain and store the value. Refer to X0D for set/reset timing. |
Y0E | Assigning offset or gain calibration mode | This is used to set when it is started to calibrate offset/gain and to reset when they has been calibrated. |
Y0F | Requesting to clear an error | This is set to clear the error. Refer to X0F(Flag indicating error occurring in D/A module) for set/reset timing. |