User Controlled Loss in Weight Batch

This mode performs loss in weight batching but the comparator output is dependant only on the net weight data. This mode, while being more flexible than the automatic mode described in section "Automatic Loss in Weight Batch", is more difficult to implement. No compensation is performed in this mode.
After starting of this mode batch control, the batching signal (X6/7/8/9) is turned on until when the WGSTOP instruction or ‘Batch Stop’ command (code 3) with Y2/3/4/5 signal is issued by sequence program.

 

image-20240325-061914.png

Dribble Flow Weight

offset 98, 144, 190, 236

If the net weight is below of this weight, the dribble flow gate signal is turned on.

 

Full Flow Weight

offset 100, 146, 192, 238

If the net weight is below of this weight, the full flow gate signal is turned on.

 

Over Weight

offset 102, 148, 194, 240

If the net weight is below of this weight, the over signal is turned on.

 

Under Weight

offset 104, 150, 196, 242

If the net weight is above of this weight, the under signal is turned on.

 

Max. Hopper Weight

Max. Hopper Weight offset 114, 160, 206, 252

If the gross weight is above of this weight, the ‘Hopper Gate’ bit (Bit 6) of control signal (offset 3, 18, 33, 48) is turned on.

 

image-20240325-061940.png