User Controlled Normal Batch
This mode performs normal batch weighing but the comparator output is dependant only on the net weight data. This mode, while being more flexible than the automatic mode described in section "Automatic Normal Batch", is more difficult to implement as the actual full flow and dribble flow outputs must be controlled by a sequence program. No compensation is performed in this mode.
After starting of this mode batch control, the batching signal (X6/7/8/9) is turned on until when the WGSTOP instruction or ‘Batch Stop’ command (code 3) with Y2/3/4/5 signal is issued by sequence program.
Dribble Flow Weight
offset 98, 144, 190, 236
If the net weight is above this weight, the dribble flow gate signal is turned off.
Full Flow Weight
offset 100, 146, 192, 238
If the net weight is above this weight, the full flow gate signal is turned off.
Over Weight
offset 102, 148, 194, 240
If the net weight is above this weight, the over signal is turned on.
Under Weight
offset 104, 150, 196, 242
If the net weight is below this weight, the under signal is turned on.