Basic Configuration Data
Offset 70–95, 116-141, 162-187, 208-233
The shared memory area of offset 70-235 holds the basic configuration data for operation. Those configuration data can be modified through the CICON or sequence program of CPU. The case of CICON is described in the previous section (3.2 Basic configuration with the special program).
Weighing Mode (offset 70, 116, 162, 208)
This field holds the encoded operating mode. For more information of each operating mode, please refer to the section of ‘Batch Program’
Set Value | Mode |
H0000 | Indicator Mode |
H0001 | Automatic Normal Batch |
H0002 | Automatic Loss in Weight Batch |
H0003 | User Controlled Normal Batch |
H0004 | User Controlled Loss in Weight Batch |
H0005 | Comparator Mode |
H0006 | Weight Sorting |
H0007 | Dynamic Weighing (Fluid material) |
H0008 | Dynamic Weighing (Solid material) |
H0009 | Disabled |
Other Parameters :
Please refer to the section of ‘Basic configuration with the special program’.