User Controlled Normal Batch

This mode performs normal batch weighing but the comparator output is dependant only on the net weight data. This mode, while being more flexible than the automatic mode described in section "Automatic Normal Batch", is more difficult to implement as the actual full flow and dribble flow outputs must be controlled by a sequence program. No compensation is performed in this mode.
After starting of this mode batch control, the batching signal (X6/7/8/9) is turned on until when the WGSTOP instruction or ‘Batch Stop’ command (code 3) with Y2/3/4/5 signal is issued by sequence program.

 

image-20240325-061836.png

Dribble Flow Weight

offset 98, 144, 190, 236

If the net weight is above this weight, the dribble flow gate signal is turned off.

 

Full Flow Weight

offset 100, 146, 192, 238

If the net weight is above this weight, the full flow gate signal is turned off.

 

Over Weight

offset 102, 148, 194, 240

If the net weight is above this weight, the over signal is turned on.

 

Under Weight

offset 104, 150, 196, 242

If the net weight is below this weight, the under signal is turned on.

 

image-20240325-061856.png