Internal Flag(Relay) F

This is used to get information about the state or PLC, time, day and so on.

 

F Zone

Function

Description

F0000

F0000 : Run Mode

In case of RUN Mode, ON

F0001 : Program Mode

In case of Program Mode, ON

F0002 : Pause Mode

In case of Pause Mode, ON

F0003 : Debug Mode

In case of Debug Mode, ON

F0007 : Remote Mode

In case of Remote Mode, ON

F000F : Execute Stop Instruction

In case of Executing Stop, ON

F0010

F0010 : Always ON

Always ON

F0011 : Always OFF

Always OFF

F0012 : ON at first scan only

ON for a SCAN

F0013 : OFF at first scan only

OFF for a SCAN

F0014 : Toggle at each scan

Invert every scan Unused

F0020

Reserved

-

F0030

F0030 : Error

In case of error, ON

F0031 : Warning

In case of warning, OFF

F0032 : WDT Error

In case of Watchdog Timer error, ON

F0033 : I/O combined Error

In case of I/O combined Error, ON

F0034 : Battery voltage low

In case of low voltage than standard, ON

F0037 : Forced ON/OFF

In case of forced ON/OFF to I/O, ON

F0040

F0040 ~ 7 : I/O Error

If reserved I/O and mounted I/O are different, number of different SLOT stored. (0 ~ 11)

F0048 ~ F : I/O Error

If reserved I/O and mounted I/O are different, number of different expansion stored. (0 ~ 11)

F0050

Error Code

-

F0070

In case of Dual Port RAM Access Error, Details

F0070 ~ 7

Number of slot(0 ~ 11) stored.

F0078 ~ F

Number of expansions (0 ~ F) stored.

F0080

CPU Type

CP CPU:

CM1-CP3A: 3A, H3341

CM1-CP3B: 3B, H3342

CM1-CP3P: 3P, H3350

CM1-CP3U: 3U, H3355

CM1-CP3E: C3, H4333

 

CM1-CP4A: 4A, H3441

CM1-CP4B: 4B, H3442

CM1-CP4C: 4C, H3443

CM1-CP4D: 4D, H3444

CM1-CP4U: 4U, H3455

CM1-CP4E: C4, H4334

CM1-CP4F: CF, H4346

CM1-BP:

CM1-BPxx: H4230 = B0

XP CPU:

CM1-XP1A = H5811 = 'X' + H10 + H01

CM1-XP2A = H5821 = 'X' + H20 + H01

CM1-XP3A = H5831 = 'X' + H30 + H01

CM1-XP1R = H5813 = 'X' + H10 + H03

 

CM1-XP1B = H6D41 = 'm' + 'A'

CM1-XP2B = H6D42 = 'm' + 'B'

CM1-XP3B = H6D43 = 'm' + 'C'

 

CM1-XP1E = H7831 = 'x' + '1'

CM1-XP2E = H7832 = 'x' + '2'

CM1-XP3E = H7833 = 'x' + '3'

 

CM1-XP1F = H6631 = ‘f’ + 1

CM1-XP2F = H6632 = ‘f’  + 2

CM1-XP3F = H6633 = ‘f’  + 3

CM1-XP1S = H7331 = ‘s’ + 1

 

CM1-XP1G = H6731 = ‘g’ + 1

CM1-XP2G = H6732 = ‘g’ + 2

CM1-XP3G = H6733 = ‘g’ + 3

CM1-XP1T = H7431 = ‘t’ + 1

 

CM1-XP1U = H7A31 = ‘z’ + 1

F0090

F0090 : 0.02s Interval SYSTEM CLOCK

ON / OFF in a constant interval under RUN operation.

(During operation, initial value is 0)

F0091 : 0.1s Interval SYSTEM CLOCK

F0092 : 0.2s Interval SYSTEM CLOCK

F0093 : 1s Interval SYSTEM CLOCK

F0094 : 2s Interval SYSTEM CLOCK

F0095 : 10s Interval SYSTEM CLOCK

F0096 : 20s Interval SYSTEM CLOCK

F0097 : 1m Interval SYSTEM CLOCK

F0100

F0100 : USER CLOCK 0

User can use "DUTY" instruction to cycle On / Off.

(Initial setting is Off)

F0101 : USER CLOCK 1

F0102 : USER CLOCK 2

F0103 : USER CLOCK 3

F0104 : USER CLOCK 4

F0105 : USER CLOCK 5

F0106 : USER CLOCK 6

F0107 : USER CLOCK 7

F0108 - F10F : Not Use

F0110

F0110 : In case of operation error, ON

To modify whenever operation

F0111 : Zero Flag

Zero Flag

F0112 : Carry Flag

Carry Flag

F0118 : In case all outputs OFF, ON

In case all outputs OFF, ON

F0119 : DPRAM Access Error

Details are stored in F0007

F0120

F0120 : < Flag

Less, ON

F0121 : = Flag

Less or equal, ON

F0122 : = Flag

Equal, ON

F0123 : > Flag

Greater, ON

F0124 : = Flag

Greater or equal, ON

F0125 : ≠ Flag

Not equal, ON

F0130

On Slot 0, I/O is mounted

F0140

On Slot 1, I/O is mounted

F0150

On Slot 2, I/O is mounted

F0160

On Slot 3, I/O is mounted

F0170

On Slot 4, I/O is mounted

F0180

On Slot 5, I/O is mounted

F0190

On Slot 6, I/O is mounted

F0200

On Slot 7, I/O is mounted

F0210

On Slot 8, I/O is mounted

F0220

On Slot 9, I/O is mounted

F0230

On Slot A, I/O is mounted

F0240

On Slot B, I/O is mounted

F0250

On Slot C, I/O is mounted

F0260

On Slot D, I/O is mounted

F0270

On Slot E, I/O is mounted

F0280

On Slot F, I/O is mounted

F0290

Reserved

F0300

Minimum Scan Time (Unit : msec)

F0310

Current Scan Time (Unit : msec)

F0320

Maximum Scan Time (Unit : msec)

F0330 ~ F0390

Reserved

F0400

Stored year in clock data (EX : 2001)

F0410

Stored month and date in clock data (Upper : Month , Lower : Date)

F0420

Stored day of the week and hour in clock data (Upper : Weekday, Lower : Hour)

F0430

Stored minute and second in clock data (Upper : Minute, Lower : Second)

F0440

Reserved

F0450

Year when power is On is stored. (EX " 2001)

F0460

Month and day when power is ON is stored.

F0470

Day of the week and Hour when power is ON is stored.

F0480

Minute and Second when power is ON is stored.

F0490

Reserved

F0500

Count AC Fail

F0510

Year in case of AC Fail is stored. (EX : 2001)

F0520

Month and Day in case of AC Fail is stored.

F0530

Day of the week and Hour in case of AC Fail is stored.

F0540

Minute and Second in case of AC Fail is stored.