Executing a project in the UA Web version

Executing a project in the UA Web version

When you try to open a project of the lower version with the higher version of UltimateAccess Web, a message will appear asking if you wish to upgrade the project. In this window, you can back up the project and edit it on the higher version of UltimateAccess Web 1.0.

project_backup.png

Item

Description

Path

Saves the backup file in the assigned path. You cannot save the file in the identical project folder.

Backup Now

Saves the backup file in the path and opens the project in the higher version.

Open

Does not back up the project and opens the project in the higher version.

Cancel

Does not execute the project of lower version and goes back to the start-up screen.

  • The version that can be changed to UltimateAccess Web 1.0 project is only the v3.90 project.

  • If you want to change a previous version of the project, please upgrade the project using the v3.90 version of the Designer.

Converting UltimateAccess old version project (3.90v) to UltimateAccess Web 1.0 project

Converting UltimateAccess old version project (3.90v) to UltimateAccess Web 1.0 project

  1. Back up project

project_backup.png

When executing UltimateAccess Web 1.0 project, as shown above […] Click the ] button to specify the path, then click the [Open after backup] button to back up the project. If backup is not supported, project changes will not proceed.

  • After changing to UltimateAccess Web 1.0 project, it cannot be restored to the previous version, so the conversion process must be performed after a backup.

 

  1. Project Environment Settings - Basic

After the change is complete, enter the DBMS information to be connected to the project and click [Confirm] to proceed.

 

After confirmation, click [Confirm] to proceed with the project conversion process.

 

  1. Project Environment Settings - UltimateAccessX Environment Settings

After conversion is complete, be sure to proceed with web settings and initial screen settings by clicking [Tools] - [CimonX Environment Settings].

 

After setting, right-click on the [Monitoring Control Screen] in the project workspace and proceed to [Save All (S)].

 

  1. Project Environment Settings - Monitor Settings

After conversion is complete, click [File] - [Multimonitor Settings] to proceed in the same way as the existing project monitor settings.

UltimateAccess Web 1.0 no longer supports fixed pages. Please be careful when setting up after converting the project.

 

  1. Project Environment Settings - Other Settings

The functions that require additional settings after conversion and the functions and objects that are no longer supported are as follows.

 

Settings that require additional settings

  • Data Logging

  • Alarm Configuration

  • Security

 

Unsupported drawing object

  • Log Data Sheet

  • Part

  • RTGraph

  • Dynamic Image

  • ActiveX

  • Insert Object

  • List Box

  • Comobo Box

  • Data Grid

  • Video Capture

  • List Control

  • Calendar Control

  • Fixed Page

 

Unsupported Features

  • Hot-Key

  • User Menu

  • Group Editor

  • Trend Panel

  • Group Scheduler

  • Part Editor

  • Min Report

  • Dyamic Image

  • Audio Player

  • Fast Trend

 

 

  1. Etc