General Specifications(CM1 Load cell)
Items | Specification | Standards | ||||
Op. Temp | -10℃~65℃ | - | ||||
St. Temp | -25℃~80℃ | - | ||||
Op. Hum | 5~95%RH, Not Condensed | - | ||||
St. Hum | 5~95%RH, Not Condensed | - | ||||
Vibration | In case of intermittent vibration | IEC 61131-2 | ||||
Frequency | Acceleration | Amplitude | Sweep | |||
5≤f<9Hz | - | 1.75mm | 10 times in X, Y, Z | |||
9≤f≤150Hz | 9.8m/s2{1G} | - | ||||
In case of continuous vibration | ||||||
Frequency | Acceleration | Amplitude | Sweep | |||
5≤f<9Hz | - | 3.5mm | 10 times in X, Y, Z | |||
9≤f≤150Hz | 4.9m/s2{0.5G} | - | ||||
Shock | Max. shock Acc. : 147m/s2 {15G} Time : 11ms Pulse wave : Half sine wave pulse(3 times in X, Y, Z) | IEC 61131-2 | ||||
Noise | Square wave impulse noise | ±2kV | CIMON Standard | |||
Electro-static discharge | ±4kV (Contact), ±8kV (Air) | IEC 61131-2 IEC61000-4-2 | ||||
Radiated electro-magnetic field | 80 ~ 1000 MHz,10V/m | IEC 61131-2 IEC61000-4-3 | ||||
Fast transient bust noise (Voltage) | CPU, Power | 2kV | IEC 61131-2 IEC61000-4-4 | |||
Digital/Analog I/O (AC) | 2kV | |||||
Digital/Analog I/O (DC) | 1kV | |||||
Communication | ||||||
Ambient Conditions | No corrosive gas and no dust | |||||
Altitude | 2,000m or less | |||||
Pollution | 2 or less | |||||
Cooling | Natural Air Cooling |