Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

CIMON Xpanels are capable of sharing tag values with CIMON-SCADA through an Ethernet connection.

To use an Xpanel as a data server, you will need to register it as an I/O device in the SCADA project. See the Additional Configuration section for more information.

For this feature, an Xpanel provides two memory areas:

...

Each memory area is composed of 5,000 buffers, which are used exclusively to communicate with CIMON-SCADA.

To use an Xpanel as a data server, you will need to register it as an I/O device in the SCADA project. See the Additional Configuration section for more information.

Note

Xpanel must be configured with a fixed IP address to use this function.

...

OPC UA Server

...

Item

Description

Device Name

Allows the user to assign a name for the selected data server device.

Device Protocol

Allows the user to select a protocol for a device.

Use All Tags

Allows the user to upload all of the tags in the project file to the data server. This option is only available for OPC UA SERVER and MQTT JSON Publisher device protocols.

Server Name

Enter the name of server.

Application URI

Enter the Uniform Resource Identifier (URI) to locate the asset on a network.

Application Name

Name of the URI application.

Port

Assign a port number for the Data Sever.

Modbus TCP

...

Item

Description

Device Name

Allows the user to assign a name for the selected data server device.

Device Protocol

Allows the user to select a protocol for a device.

Host

Assign an IP Address for the Data Server

Port

Assign a port number for the Data Sever.

MQTT JSON Publisher

...

Item

Description

Device Name

Allows the user to assign a name for the selected data server device.

Device Protocol

Allows the user to select a protocol for a device.

Use All Tags

Allows the user to upload all of the tags in the project file to the data server. This option is only available for OPC UA SERVER and MQTT JSON Publisher device protocols.

Broker Address

Assign an IP Address for the Broker Device.

Port

Assign a port number for the Data Sever.

Client ID

The timeout feature periodically checks whether the connection is still valid. If a requested frame is not received in the assigned time, it will be processed as a communication failure. This option is not applied if the protocol is TCP/IP. Values represent multiples of 100ms. For example, a value of 10 represents 1000ms or 1 second.

Use Clean Session

Enables connecting to the MQTT broker using a clean session, or a non-persistent connection.

Keep Alive

Assign the number of communication retry attempts after a communication failure.

Use SSL

Allows the user to upload all of the tags in the project file to the data server. This option is only available for [OPC UA SERVER] and [SPARKPLUG CLIENT] device protocols.

Key Pair

The SSL box must be checked to access this feature.

Trust Store

Password to the truststore file.

Use MQTT Passwords

Enable/disabled MQTT passwords feature.

MQTT Username

Create MQTT username.

MQTT Password

Create MQTT password.