CIMON Xpanels are capable of sharing tag values with CIMON-SCADA through an Ethernet connection.

...

OPC UA Server

...

Item

Description

Device Name

Allows the user to assign a name for the selected data server device.

Device Protocol

Allows the user to select a protocol for a device.

Use All Tags

Allows the user to upload all of the tags in the project file to the data server. This option is only available for OPC UA SERVER and SPARKPLUG CLIENT device protocols.

Host

Assign an IP Address for the Data Server

Ethernet Type

Allows the user to choose between UDP & TCP.

Port

Assign a port number for the Data Sever.

Modbus TCP

...

Item

Description

Device Name

Allows the user to assign a name for the selected data server device.

Device Protocol

Allows the user to select a protocol for a device.

Host

Assign an IP Address for the Data Server

Port

Assign a port number for the Data Sever.

Sparkplug Client

...

Item

Description

Device Name

Allows the user to assign a name for the selected data server device.

Device Protocol

Allows the user to select a protocol for a device.

Use All Tags

Allows the user to upload all of the tags in the project file to the data server. This option is only available for OPC UA SERVER and SPARKPLUG CLIENT device protocols.

Broker Address

Assign an IP Address for the Broker Device.

Port

Assign a port number for the Broker Device.

Client ID

The timeout feature periodically checks whether the connection is still valid. If a requested frame is not received in the assigned time, it will be processed as a communication failure. This option is not applied if the protocol is TCP/IP. Values represent multiples of 100ms. For example, a value of 10 represents 1000ms or 1 second.

QOS

Assign the number of communication retry attempts after a communication failure.

Use SSL

Allows the user to upload all of the tags in the project file to the data server. This option is only available for OPC UA SERVER and SPARKPLUG CLIENT device protocols.

CA Path

Cert Path

Private Key Path

Uses random generated numbers that must correspond with the generated key from CSR (Certificate Signing Request.)

Use MQTT Passwords

MQTT Username

MQTT Password

Private Key Password

Running Mode

Polling Rate (ms)

Namespace

Group ID

EoN ID

Gateway gRPC Server

...

Item

Description

Device Name

Allows the user to assign a name for the selected data server device.

Device Protocol

Allows the user to select a protocol for a device.

Host

Assign an IP Address for the Data Server

Port

Assign a port number for the Data Sever.