FLT Conversion
FLT, FLTP, DFLT, DFLTP
FLT instruction converts binary data to float value and save the result in Destination (assigned device address).
(It supports only in XP and PLC-S CPU series)
| |
S | Source |
D | Destination (Float value) |
Instruction | Device address | No. of Steps | Flag | |||||||||||||||
M | X | Y | K | L | F | T | C | S | Z | D | @D | Int. |
| Error | Zero | Carry | ||
FLT(P) DFLT(P) | S | o | o | o | o | o | o | o | o | - | o | o | o | o | 4 | o | - | - |
D | o | - | o | o | o | - | - | - | - | o | o | o | - |
FLT(P)
Functions
Convert S(16bit binary data) to float value and save the result in the Destination.
The range of binary data in S is -32,768 ~ 32,767.
Example)
If M00 is ON, save 1234 to D90 and convert D90 to float value and then save the result in D100.
DFLT(P)
Functions
Convert S(32bit binary data) to float value and save the result in the Destination.
The range of binary data in S is -2,147,483,648 ~ 2,147,483,647.
Example)
If M00 is ON, save 12345678 to D90 and convert D90 to float value and then save the result in D100.