이 문제는 PLC 이더넷 모듈 별 동시접속 가능 수 조건이 있습니다.

동시 접속 가능 수 조건

형명

CM1-EC01A

CM1-EC10A

CM1-EC10B

CM1-EC10C

CM3-SP32

16MD(E)

CM3-SP01EET

CM1-EC01DNP

CM1-EC04DNP

데이터전송속도

10BASE-T

10BASE-T

100BASE-TX

100BASE-FX

10BASE-T

100BASE-TX

10BASE-T

100BASE-TX

10BASE-T

100BASE-TX

10BASE-T

 

 

동시접속 가능 수

 

9EA

UDP 9 Services

TCP 9 Services

16EA

UCP 16 Services

TCP 16 Services

16EA

UCP 16 Services

TCP 16 Services

16EA

UCP 16 Services

TCP 16 Services

6EA

UDP 6 Services

TCP 3 Services

12EA

UDP 12 Services

TDP 12 Services

EC01DNP

: Single Host

EC04DNP

: 4 Hosts

 

S

E

R

V

I

C

E

Loader

O (UDP)

O

HMI Protocol

O (TCP,UDP)

X

MODBUS/TCP

Slave

O

X

MODBUS/TCP Master

X

O

O

X

X

O

X

PLC Link(전용)

O

X

X

X

X

X

X

PLC Link(공용)

O

O

O

X

X

X

X

고속PLC Link

X

O

O

X

O

O

X

DHCP

X

X

X

O

O

O

X

DNP3

X

X

X

X

X

X

O

O : 지원 , X : 지원안함