Communication Setup: Xpanel

Create a new device

To configure the communication device of LSIS PLC, go to [Tools] - [I/O device] or click the (blue star) icon in the main menu. The ‘I/O Configuration’ dialog box will show up. Click on the [New Device] button.

I/O Device Name: Give a device name. This name will be used in the Tag configuration window of the database accompanied by the Station Name.

Select a device type

After selecting [Ok] on previous step, the ‘Ethernet Communication Configuration’ dialog box will pop up as shown in following picture.

Select ‘Fatek PLC Enet’ in the ‘Device Type’ dropdown menu, and choose appropriate communication parameters. Those parameters must be matched with the PLC.

Create a station

Move to [Station] tab of the ‘Ethernet Communication Configuration’ dialog box and click [Add Station]. In this dialog box, all the connected PLC stations can be configured and registered to the Xpanel.

Station Name: Give a name to the PLC. This name will be used in the database window accompanied by the 'Device Name' .

Station Type: Choose the 'FATEK PLC' (no other type can be selected).

Network ID: This field has no meaning in this driver (ignored during runtime).

IP Address: Input IP Address FATEK PLC

Socket Port No.: Input Major Port FATEK PLC.

16Bit Data Swap: This field has no effect.

32Bit Data Swap: This field has no effect.

String Data Swap: This field has no effect.

Using Checksum: This field has no effect.

Comm. Error Message Pop up: When this item is checked, Xpanel displays a communication error message box for every Rx and Tx error. Otherwise (unchecked), Xpanel does not display a message for communication errors. This message box will close automatically after a few seconds.

Communication Setting: FATEK PLC

1. IP Setting

  • Run ‘Fatek Ethernet Module Configuration Tool’.

  • To scan the Fatek PLC, press the [Scan Map] button.

  • Double click the item on the scan result to edit the Ethernet setting.

  • Go to the [General] tab to set IP address, Subnet Mask, and Gateway.

  • Check the ‘Remote Config’ box to enable it.

  • Select ‘Server’ for the ‘Operation Mode’.

  • Go to the [Misc.] tab to set the Major Port, on the 'FATEK Service Port Number'.

  • After finishing the parameter setting, press the [OK] button.

Address Notation

(1) Word tag is supported by 16-Bit only.

(2) Digital address is used only for digital tags.

(3) 32-Bit address is used only for 32-Bit analog tags.

Wiring Diagram

This interface is used to communicate between the equipment and TOUCH/PPC by the Ethernet code of practice. This interface is satisfied with standard IEEE802.3 of the 10Base-T/100Base-TX.

You can configure the cable and allocation pin number of RJ45 as shown below.

Direct Cable: Host ↔︎ HUB

Crossover Cable: Host ↔︎ Host