Item | Description |
New Tag | There are several methods to create a new tag:
|
Edit Tag | There are several methods to edit a tag:
|
Delete Tag | There are several methods for deleting a tag:
|
Copy Tag | Select the tag to copy/cut from the tag list. Copy or cut the tag with any of the methods shown below: |
Drag & Drop | Tags can also be copied and pasted by dragging and dropping:
|
...
Item | Description | |
Initial Value | Assign the initial tag value to be loaded to the tag at project startup. | |
Data Type | Select the data type (bit encoding) of the tag value to use within XpanelDesigner. Refer to the table below for a description of each data type. | |
Clipping | With this option, when the analog value exceeds the specified Min/Max range, a warning message will appear and the value will not be recognized. | |
Scale | Converts the original input data into a new value using one of two methods. Note that the behavior of the ‘Eng. Data’ Min/Max valuess values change depending on whether the “Scale” box is checked or not. | |
Scale/Offset (Only visible when Scale is selected) | To use the Scale/Offset method, check the “Scale” box, then enter the Scale and Offset values in the ‘Scale/Offset’ field. With this option, the tag value will be calculated using the formula below: Tag Value = (Input Value * Scale) + Offset Example: Select an analog tag with data type UINT16. When Scale is 0.1 and Offset is 10: Minimum value: (0 * 0.1) + 10 = 10, For a given tag value, the corresponding input value can be calculated using the formula below: Input Value = (Tag Value – Offset) / Scale | |
Min./Max. (Visible when Scale is not selected) | To use the Min/Max method, uncheck the “Scale” box, then enter the Minimum and Maximum values in the ‘Raw Data’ field. With this option, the tag value will be linearly scaled so that that the Raw Data minimum is converted to the Eng. Data minimum and the Raw Data maximum is converted to the Eng. Data maximum. Intermediate values are scaled linearly. For a given input (raw) value, the exact output (tag) value can be calculated using the formula below: Tag Value = (Input Value – Raw Data Min) / (Raw Data Max – Raw Data Min) * (Eng. Data Max – Eng. Data Min) + Eng. Data Min Example: Select an analog tag with data type Float. Set the Raw Data minimum to 0 and the maximum to 1. Set the Eng. Data minimum to 0 and the maximum to 100. Now, PLC values (on the left) will be converted to the following tag values (on the right): -17.0 becomes 0 Any input value below the Raw Data minimum will be converted to the Eng. Data minimum. Any input above the Raw Data maximum will be converted to the Eng. Data maximum. For a given tag value, the corresponding input value can be calculated using the formula below: Input Value = (Tag Value – Eng. Data Min) / (Eng. Data Max – Eng. Data Min) * (Raw Data Max – Raw Data Min) + Raw Data Min |
...