Create a new device | For creating a new device activate the menu [Tools] → [I/O Devices] or the I/O Device Name: Give the device a name. This name will be used in the tag configuration window of the database accompanied by the ‘Station Name’. | |
Select a network type
| I/O Device Name: SAMSUNG BRAIN Series After selecting the [Ok] button of the previous step, the ‘Serial Communication Configuration’ dialog box will be popup as shown in the following picture: In this window, select the Device Type SAMSUNG ‘SAMSUNG BRAIN SeriesSeries’ and configure the proper serial communication parameters. Ensure that those parameters are matched with the device's configuration. See the Communication Configuration section for more information. | |
Create a station | Move to the [Station] tab of [Serial Communication Configuration] the ‘Serial Communication Configuration’ dialog box. In this dialog box, all the connected PLC stations can be configured and registered to the Xpanel. Each field can be configured with the following rules.: | |
Station Name | Give a name to the PLC. This name will be used in the database window accompanied by the Device Name‘Device Name’. | |
Station Type | Choose the type of connected PLC among the SPC Series‘SPC Series’. | |
Network ID | N/A | |
Station No. | Specify a decimal number between 1 and 190. The PLC station number must match this number. | |
16Bit Data Swap | This option swaps bytes for all word- or double-word-sized data. The following diagram shows an example of byte-swapping: Almost all data types will be influenced by this option except INT8 / UINT8 / BCD8 / UBCD8. | |
32Bit Data Swap | This option swaps words of all double-word-sized data. The following diagram shows an example of word swapping: Tag values with data types INT32 / UINT32 / BCD32 / UBDC32 / FLOAT will be influenced by this option. | |
String Data Swap | Swaps the upper and lower bytes of string word data. | |
Using Checksum | This field has no effect. This driver always uses a BCC checksum. | |
Comm. Error Message Popup | Use a pop-up message when a communication error occurs. |
| Address
See the Communication Configuration section for more information about the remaining parameters.
Address & Function Codes
The following table shows the list of valid address range used with the FARA PLC. The character symbol has to be placed in the first position of the address string. The address number follows the character symbol.
Area | Symbol | Analog | TAGTag | Digital | TAGTag | Remark |
Ext. Input / Output | R | R000 - R127 | R000.0 - R127.15 | |||
LINK | L | L000 - L063 | L000.0 - L063.15 | |||
Internal Relay | M | M000 - M127 | M000.0 - M127.15 | |||
KEEP Relay | K | K000 - K127 | K000.0 - K127.15 | |||
Special internal Output | F | F000 - F015 | F000.0 - F015.15 | |||
Word Register Timer / Counter | W | W000 - W3071 |
|
| Communication
Communication Cable Wiring
...