※ Please refer to the ‘Multi-Language Setup’ section for more information.
...
If using a device address for column control, you can configure the details by pressing the button.
...
Item | Description | |
Data Type | Select the data type ('Digital', ‘Analog’, or ‘String’) to be used for the column control. This option is the same as the Bit/Word dropdown menu in the [Language Configuration] window. With ‘Digital’, you can only select column 0 or 1. With ‘Analog’, the value assigned to the device address will be the number of the column selected. Only values between 0 and 15 will be recognized. Values exceeding 15 will follow the configuration in the [Option] window. | |
I/O Device | Selects a device to access from the list of I/O devices registered in the current project. | |
Device Address | Assign the device register and address for the column control. | |
Device Type | Displays a list of available device registers based on the selected I/O device and the chosen data type (Digital or Analog). | |
Address | Enter the address of the device. The address format may differ depending on the data type (BIT/WORD), the selected I/O device, and the address type. | |
Device Address | You can use this keypad to input the address without a keyboard. Enter the address in decimal or hexadecimal depending on the device type. | |
Option
| The [Option] button is activated when the ‘Analog’ data type is selected.
| |
Data Type | You can select the analog data type from the following list: INT8, INT16, INT32, UINT8, UINT16, UINT32, BCD8, BCD16, BCD32, UBCD8, UBCD16, UBCD32, or Float . UINT16 is the default type. | |
Internal Data | Enter the value range to be used by Xpanel. The default range is from 0 to 65535. When you select the ‘Clipping’ option, a warning message will appear when the value exceeds the assigned range, and the value will not be used. | |
Raw Data | Enter the value range which will be input by the PLC. See section 4.1 for more information on value scaling. | |
Scale | This option rescales the PLC data from the Raw Data range to fit within the Internal Data range. See section 4.1 for more information on value scaling. |
...
Note: If you use a password for your project, be sure to store it in such a way that 1) it will not be lost, and 2) it cannot be accessed by anyone without proper permission. For security reasons, CIMON PowerTran cannot help with retrieving a lost password. |
...
Item | Description |
New Password | This is used to setup set up the password for the project. The password must meet the following criteria:
While being entered, the password will be displayed as ‘****’. |
Reenter New Password | Enter the password again for confirmation. |
Change Password | If a password is already configured for the project, the following [Change Password] dialog box will appear before a new password can be created. Enter the current password in the text box, then press [Ok]. |
OK | Saves and applies the new password. |
Cancel | Cancels the password setup and goes back to the [Project Properties] window. |
...
Item | Description | ||
Select the Model | Select the target Xpanel model. You can select the following models: XT05S, XT06C, XT08C, XT10C, XT12C, XT05M mono, XT04C, XT07C, XT15C, XT10CC, XT07C-R, or CM-NP/iNP. You cannot select Hybrid Xpanel. To use a project with Hybrid Xpanel, you must create a new project and select the “Hybrid” option. Alternatively, you can configure the I/O Device options to match those of a Hybrid Xpanel project. | ||
Back Up | Selecting this option backs up the current project before conversion. When this option is selected, the ‘Back Up Prj. Name’ and ‘Back Up Prj. Path’ fields are enabled. | LX Series | This box allows the project to work with the new LX Series of Xpanel devices. Because the series is still in testing, functionality is currently limited. Be sure to back up your project before conversion. The LX series contains…
※ All scripts used in the project must be translated manually when converting to the ‘LX series’ option. ※ Features not yet supported in the LX series:
※ Communication drivers currently supported in the LX series:
|
Back Up Prj. Name | Enter the name of the backup project. You must enter the path to the project’s parent directory before specifying the project name. The complete project directory will be generated automatically while editing the project name. You may not use the special characters shown in the following message. Underscores (“_”) and dashes (“-”) are allowed. | ||
Back Up Prj. Path | Select the parent directory path where the backup project will be saved. Once a project name is entered, the full path will be placed here automatically. | ||
Convert | The project will be backed up and converted. Do not edit the project or perform other actions on the PC until conversion is complete, as this may cause the system to overload. If you did not select the ‘Back Up’ option, an additional prompt will ask you to confirm your choice. |
...