Item | Description | |
Touch Condition Setting | Logical operations can be used to control touch features. When the result of a logical operation is True, the touch feature operates; otherwise it does not. | |
Action Delay Setting | Sets a delay option that executes by a set number of seconds. This option will be executed only when the button is pressed and held down for the assigned value. The value you can assign is from 1 (100msec100 msec) to 30 (30000msec30000 msec) seconds. Or you can input an analog tag name to specify delay time according to the assigned value. | |
On Delay | When touching the object for the set amount of time, the assigned action set in ‘Touch Down’ would run. If untouched before reaching the set amount of time, the object would not operate. ‘On Delay’ is usable for the ‘Touch Down’ action. The ‘Touch Up’ action operates with no relation to ‘On Delay’. | |
Off Delay | The assigned action would operate when releasing the object after the set amount of time (Delay time). ‘Off Delay’ is usable for the ‘Touch Down’ or ‘Touch Up’ action. | |
Double Touch | The assigned action would operate when touching the object and retouch in intervals. ‘Double Touch’ is usable for the ‘Touch Down’ or ‘Touch Up’ action. | |
Display Delay Status | When this option is selected, the ‘Delay’ status will be added in the ‘Shape Select’ window. While the ‘Delay setting’ is operating, the shape of the switch is changed into ‘Delay’ status so that you can view the delay time. ※ ‘Display Delay Status’ function is supported in XpanelDesigner 2.53 and above versions. | |
Visible | When the option is selected, enter the tag name in the input field to specify the tag for visible condition. When the visible condition is satisfied, the corresponding switch object will appear. ※ ‘Visible’ function is supported in XpanelDesigner 2.53 and above versions. | |
ON | The switch object appears when the assigned digital tag value is ON(1) or the analog tag value is bigger than 0. | |
OFF | The switch object disappears when the assigned digital tag value is OFF(0) or the analog tag value is 0. | |
Security | Sets a security level on the object. (1-10) ※ Please refer to the ‘Security’ manual for more information. |
...