OpenPort

...

Opens the serial port.

...

Function

...

In this section, you can find The table below lists functions and subroutines frequently used for controlling I/O devices. For more detailed information about each function, please refer to the next section.

...

(blue star)

...

All functions must be used with brackets.

...

Command

...

Description

...

Communication

...

Function

...

OpenPort

...

Opens the serial port.

...

Function

...

ClosePort

...

Closes the serial port.

...

Function

...

SendByte

...

Sends byte data with the selected port.

...

Function

...

SendString

...

Sends string data with the selected port.

...

Function

...

ReceiveByte

...

Receives data with the selected port.

...

Function

...

GetCommStatus

...

Checks the selected station’s communication status.

...

Subroutine

...

EnableDriver

...

Controls the selected station’s communication.

...

(blue star)

...

- EnableDriver() command only supports MODBUS RTU (XpanelDesigner V2.53).

- GetCommStatus() command can only be used in XpanelDesigner V2.53 or above.

PortNo., BaudRate, Parity, and Stop Bit use predefined constants. Refer to the table shown below for details.

...

Constant Name

...

Value

...

Usage

...

_COM232_

...

0

...

Uses COM1 port as RS232C mode.

...

_COM422_

...

1

...

Uses COM1 port as RS422 mode.

...

_COM485_

...

2

...

Uses COM1 port as RS485 mode.

...

_COMAUX_

...

3

...

Uses COM2 port as RS232C mode.

...

_BPS300_

...

 

...

300 bps

...

_BPS600_

...

 

...

600bps

...

_BPS1200_

...

 

...

1200bps

...

_BPS2400_

...

 

...

2400bps

...

_BPS4800_

...

 

...

4800bps

...

_BPS9600_

...

 

...

9600bps

...

_BPS19200_

...

 

...

19200bps

...

_BPS38400_

...

 

...

38400bps

...

_BPS56000_

...

 

...

56000bps

...

_BPS57600_

...

 

...

57600bps

...

_BPS115200_

...

 

...

115200bps

...

_BPS128000_

...

 

...

128000bps

...

_BPS256000_

...

 

...

256000bps

...

_PARITY_NONE_

...

 

...

NO PARITY BIT

...

_PARITY_EVEN_

...

 

...

EVEN PARITY

...

_PARITY_ODD_

...

 

...

ODD PARITY

...

_PARITY_MARK_

...

 

...

MARK PARITY

...

_PARITY_SPACE_

...

 

...

SPACE PARITY

...

_STOPBIT_ONE_

...

 

...

1 STOP BIT

...

_STOPBIT_TWO_

...

 

...

2 STOP BITS

...

_STOPBIT_ONE5_

...

 

...

1.5 STOP BIT

Functions for Communication section in Appendix 1. Please note that functions return a value, while subroutines do not.

ExampleDescription

Function

OpenPort(PortNo., BaudRate, Parity, Data Bit, Stop Bit)

Description

PortNo. (use predefined constant, _COMxxx_)

BaudRate (use predefined constant, _BPSxxx_)

Parity (use predefined constant, _PARITY_xxx_)

Data Bit (7 or 8)

Stop Bit (use predefined constant, _STOPBIT_xxx_)

This function opens the assigned serial port. You cannot use this function if the port has already been opened.

Once you opened the COM port with the script, it has to be closed with ClosePort() function.

When an error occurs during the port opening, the script will return 0. If the port is successfully opened, the script will return the value other than 0.

Example

Opens COM1 port with following options; RS485, 19200bps, No Parity, Data Bit 8, Stop Bit 1.

OpenPort(_COM485_, _BPS19200_, _PARITY_NONE_, 8, _STOPBIT_ONE_);

ClosePort

Closes the serial port.

Function

n=ClosePort(PortNo.)

Description

PortNo. (use predefined constant, _COMxxx_)

Closes the assigned serial port which is opened by the OpenPort() function.

When an error occurs during the port closing, the script will return 0. If the port is successfully closed, the script will return the value other than 0.

Example

Closes COM1 port.

ClosePort(_COM485_);

SendByte

Sends byte data with the selected port.

Function

n=SendByte(PortNo., Data)

Description

PortNo. (use predefined constant, _COMxxx_)

Data (0~255)

This function is used when you wish to transmit a data with the COM port which is opened by OpenPort() function.

Data must be a byte data in the range of 0(0x00) to 255(0xFF). If the data is greater than 255(0xFF), only the lower byte will be transmitted.

For example, if you assign Data with 0x1234, only 0x34 will be transmitted.

OpenPort() function must be used before the execution of SendByte() function.

If an error occurs during the data transmission, the script will return 0.

If the data is successfully transmitted, the script will return the value other than 0.

Example

Transmits byte data “2” through COM1 port which uses RS485 communication.

SendByte(_COM485_, 2);

SendString

Sends string data with the Sends byte data with the selected port.

Function

SendString(PortNo., Data)

Description

PortNo. (use predefined constant, _COMxxx_)

Data (Enter the String Tag or “String”)

This function is used when you wish to transmit a data with the COM port which is opened by OpenPort() function.

The Data must be assigned with string tag or string data. If you use the string data, it must be used with double quotation marks. (“ “)

OpenPort() function must be used before the execution of SendString() function.

If an error occurs during the data transmission, the script will return 0.

If the data is successfully transmitted, the script will return the value other than 0.

Example

Transmits byte data “TEXT” through COM1 port which uses RS485 communication.

SendString(_COM485_, “TEXT”);

ReceiveByte

Receives data Sends string data with the selected port.

Function

ReceiveByte(PortNo., Data)

Description

PortNo. (use predefined constant, _COMxxx_)

Data (0~255)

This function is used when you wish to receive a Receives data with the COM port which is opened by OpenPort() function.

Once you receive the data successfully, the Data (0~255) will be stored in the variable. If there is no received data until the timeout, the script will return 256.

OpenPort() function must be used before the execution of ReceiveByte() function.

Example

Receives byte data through the COM1 port which uses RS485 communication. Saves the received data at the variable ‘RxData’.

VAR RxData;

OpenPort(_COM485_, _BPS19200_, _PARITY_NONE_, 8, _STOPBIT_ONE_);

RxData = RecieveByte(_COM485_, 1000);

If(RxData < 256)

{

}

……

GetCommStatus

Checks the selected station’s communication status.

selected port.

Function

GetCommStatus(DeviceName”“DeviceName”, “StationName”)

Description

Returns the status of the assigned DeviceName ‘s StationName.. If the communication is normal, the script will return 1. If there is an error at the communication, the script will return 0.

Checks the communication status of the device “PLC”’s station “STATION”.

CommStatus = GetCommStatus(“PLC”,”STATION);

EnableDriver

Controls the selected station’s communication status.

Subroutine

EnableDriver(“DeviceName”, “StationName”, Enable/Disable)

Controls the communication of the assigned DeviceName ‘s StationName.

Enter 1 to Enable/Disable to enable the communication. Enter 0 to disable the communication.

This function only supports MODBUS RTU at XpanelDesigner V2.52.

Example

Enables the station “STATION “ of “MODBUS” device.

EnableDriver(“MODBUS”, “STATION”, 1);selected station’s communication.

To share Xpanel tags with CIMON-SCADA, or to configure Xpanel as a Modbus Slave, see the Data Server chapter. Note that the 'Xpanel Data Server' feature must be configured for SCADA to be able to communicate with the Xpanel device.

To configure Xpanel as a data bridge between devices, see the Data Bridge chapter.

To send and receive contiguous blocks of data to/from I/O devices, see the Recipe chapter.