Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Cable

No.

Color

Color

No.

Cable

1

Orange/W

Orange/W

1

2

Orange

Orange

2

3

Green/W

Green/W

3

4

Blue

Blue

4

5

Blue/W

Blue/W

5

6

Green

Green

6

7

Brown/W

Brown/W

7

8

Brown

Brown

8

Crossover Cable: Host ↔︎ Host

Cable

No.

Color

Color

No.

Cable

Image RemovedImage Added

1

Orange/W

Green/W

1

2

Orange

Green

2

3

Green/W

Orange/W

3

4

Blue

Blue

4

5

Blue/W

Blue/W

5

6

Green

Orange

6

7

Brown/W

Brown/W

7

8

Brown

Brown

8

Device Memory Range

Within XpanelDesigner, you may use the following device memory addresses to reference the connected PLC.

Direct Variable

Data type

Remark

%QX0.0.0 - %QX63.7.63

BIT

Output area

%IX0.0.0 - %QX63.7.63

BIT

Input area

%MX0 - %MX524287

BIT

Direct variable area

%MW0.0 - %MW32767.15

BIT

Direct variable area

%MD0.0 - %MD16383.31

BIT

Direct variable area

%QW0.0.0 - %QW63.7.3

WORD

Output image area

%IW0.0.0 - %QW63.7.3

WORD

Input image area

%MW0 - %MX32767

WORD

Direct variable area

%QD0.0.0 - %QD63.7.1

DWORD

Output area

%ID0.0.0 - %QD63.7.1

DWORD

Input area

%MD0 - %MD16383

DWORD

Direct variable area

Note: “Direct“ variable areas support both read and write operations.

...