Please note that Canvas can still communicate with these devices via Modbus if a specific protocol is unavailable for a given device.

...

Child pages (Children Display)

General Configuration

Please know that general configuration will appear regardless of the selected Connection Type and Device Type.

...

Item

Description

Device Name

Allows the user to assign a name for the selected I/O device.

Device Protocol

Allows the user to select a protocol for a device.

Timeout (ms)

The maximum time to wait with no response before assuming a communication failure.

Retry Count

Set the number of retries for sending a frame when communication fails.

Swap 16 (16-bit Data Swap)

This option swaps bytes for all word or double-word-sized data. The following diagram shows an example of byte-swapping:

Almost all data types will be influenced by this option except INT16 / UINT16

Swap 32 (32-bit Data Swap)

This option swaps words of all double-word-sized data. The following diagram shows an example of word swapping:

Tag values with data types INT32 / UINT32 / BCD32 / UBDC32 / FLOAT FLOAT32 will be influenced by this option.

Swap 64 (64-bit Data Swap)

This option swaps words of all quadruple-word-sized data.

Tag values with data types INT64 / UINT64 / BCD64 / UBDC64 / FLOAT64 will be influenced by this option.

Swap Float 16

Swap Float 32

Swap Double 16

Swap Double 32

Swap Double 64

Swap String

Swaps the upper and lower bytes of string word data.

String Encoding

Specifies the encoding method for reading and writing string values stored on the device. This option can be overridden for individual tags in the Edit Tag menu.

String Encoding Method

When an invalid character is encountered, the gateway will do one of the following:

  • Replace the character with "?".

  • Skip the character and continue with the next one.

  • Stop the string and truncate any remaining characters. This option can be overridden for individual tags in the Edit Tag menu.

Additional Configuration - Device Specific

Allen-Bradley EtherNet/IP

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Port

Enter the port number of the target I/O device. The default port number is 44818.

PLC Type

Enter the model of PLC for the target device.

Message Type

Allows the user to select a Tag or PCCC message type.

Use Multiple Service

Allows the user to simultaneously poll for multiple tags. This feature is not supported by all AB CPUs.

Slot Number

Enter the slot number of the target device.

...

Item

Description

PLC Type

Enter the model of PLC for the target device.

Host

Enter the IP address of the target I/O Device. The default port number is 10260 for TCP, and 10262 for UDP.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

Enter the port number of the target I/O device.

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a TCP or UDP connection.

Port

Enter the port number of the target I/O device. The default port number is 500 for either TCP/UDP.

LSIS FEnet

...

Item

Description

PLC Type

Enter the model of PLC for the target device.

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

Enter the port number of the target I/O device. The default port number is 2004 for TCP, and 2005 for UDP.

Mitsubishi MELSEC Ethernet

...

Item

Description

PLC Type

Enter the model of PLC for the target device.

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

Enter the port number of the target I/O device. The default port number is 5000 for either TCP/UDP.

Frame Type

Currently, Canvas only supports 4E.

Modbus TCP

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Port

Enter the port number of the target I/O device. The default port number is 502.

Unit Identifier

Enter the unit identifier of the target device.

OPC UA Client

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Port

Enter the port number of the target I/O device. The default port number is 4840.

Application URI

Enter the Uniform Resource Identifier (URI) to locate the asset on a network.

Enabled Encryption

Checking this box will enabled encryption. Unchecking this box will disable encryption.

Generate Encryption Certificates

Enabled by default. This feature can only be disabled by first enabling encryption. Checking this box will enable encryption certificate generation. Unchecking this box will disable encryption certificate generation.

Encryption Key Pair

Security Policy

Message Security

Server Name

Enter the name of server.

Authentication Method

Choose between anonymous or username.

Authentication Username

Enter the username for the server.

Authentication Password

Enter the password of the username for the server.

Omron FINS

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

Enter the port number of the target I/O device. The default port number is 9600 for either TCP/UDP.

Source Node ID

Enter the Source Node ID.

Source Network ID

Enter the Source Network ID.

Destination Network ID

Enter the Destination Network ID.

Destination Node ID

Enter the Destination Node ID.

Destination Unit

Enter the Destination Unit.

...

Proface FPEthernet

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Port

Enter the port number of the target I/O device.

Unit Identifier

Enter the unit identifier of the target device

The default port number is 1024.

Siemens S7

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Port

Enter the port number of the target I/O device. The default port number is 102.

Slot Number

Enter the slot number of the target device.

Rack Number

Enter the rack number of the target device.

Proface FPEthernet

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Port

Enter the port

number of the target

I/O

device.