Please note that Canvas can still communicate with these devices via Modbus if a specific protocol is unavailable for a given device.

...

Child pages (Children Display)

General Configuration

Please know that general configuration will appear regardless of the selected Connection Type and Device Type.

...

Item

Description

Device Name

Allows the user to assign a name for the selected I/O device.

Device Protocol

Allows the user to select a protocol for a device.

Timeout (ms)

The maximum time to wait with no response before assuming a communication failure.

Retry Count

Set the number of retries for sending a frame when communication fails.

Swap 16 (16-bit Data Swap)

This option swaps bytes for all word or double-word-sized data. The following diagram shows an example of byte-swapping:

Almost all data types will be influenced by this option except INT16 / UINT16

Swap 32 (32-bit Data Swap)

This option swaps words of all double-word-sized data. The following diagram shows an example of word swapping:

Tag values with data types INT32 / UINT32 / BCD32 / UBDC32 / FLOAT will be influenced by this option.

Swap String

Swaps the upper and lower bytes of string word data.

String Encoding

Specifies the encoding method for reading and writing string values stored on the device. This option can be overridden for individual tags in the Edit Tag menu.

String Encoding Method

When an invalid character is encountered, the gateway will do one of the following:

  • Replace the character with "?".

  • Skip the character and continue with the next one.

  • Stop the string and truncate any remaining characters. This option can be overridden for individual tags in the Edit Tag menu.

Additional Configuration - Device Specific

Allen-Bradley EtherNet/IP

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Port

Enter the port number of the target I/O device.

PLC Type

Enter the model of PLC for the target device.

Message Type

Allows the user to select a Tag or PCCC message type.

Use Multiple Service

Allows the user to simultaneously poll for multiple tags. This feature is not supported by all AB CPUs.

Slot Number

Enter the slot number of the target device.

Omron FINS

...

CIMON PLC (HMI Protocol)

...

Item

Description

PLC Type

Enter the model of PLC for the target device.

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

Enter the port number of the target I/O device.

Source Node ID

Enter the Source Node ID.

Source Network ID

Enter the Source Network ID.

Destination Network ID

Enter the Destination Network ID.

Destination Node ID

Enter the Destination Node ID.

Destination Unit

Enter the Destination Unit.

CIMON CI-net (CIMON-PLC)

...

Fatek FBS

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a TCP or UDP connection.

Port

Enter the port number of the target I/O device.

LSIS FEnet

...

Item

Description

PLC Type

Enter the model of PLC for the target device.

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

Enter the port number of the target I/O device.

Modbus TCP

...

Mitsubishi MELSEC Ethernet

...

Item

Description

PLC Type

Enter the model of PLC for the target device.

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

Enter the port number of the target I/O device.

Unit Identifier

Enter the unit identifier of the target device.

Siemens S7

...

Frame Type

Currently, Canvas only supports 4E.

Omron FINS

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

Enter the port number of the target I/O device.

Slot Number

Source Node ID

Enter the

slot number of the target device.

Rack Number

Enter the rack number of the target device.

LSIS FEnet

...

Item

Description

PLC Type

Enter the model of PLC for the target device.

Source Node ID.

Source Network ID

Enter the Source Network ID.

Destination Network ID

Enter the Destination Network ID.

Destination Node ID

Enter the Destination Node ID.

Destination Unit

Enter the Destination Unit.

Modbus TCP

...

Item

Description

Host

Enter the IP address of the target I/O Device

.

Ethernet Type

Allows the user to select a UDP or TCP connection

Item

Description

PLC Type

Enter the model of PLC for

.

Port

Enter the port number of the target I/O device.

Mitsubishi MELSEC Ethernet

...

Unit Identifier

Enter the unit identifier of the target device.

Siemens S7

...

Item

Description

Host

Enter the IP address of the target I/O Device

.

Ethernet Type

Allows the user to select a UDP or TCP connection

Item

Description

Host

Enter the IP address

.

Port

Enter the port number of the target I/O device.

Fatek FBS

...

Slot Number

Enter the slot number of the target

I/O Device.

Ethernet Type

Allows the user to select a UDP or TCP connection.

Port

device.

Rack Number

Enter the

port

rack number of the target

I/O

device.

Proface FPEthernet

...

Item

Description

Host

Enter the IP address of the target I/O Device.

Port

Enter the port number of the target I/O device.

...