This driver allows for communication with CIMON devices (PLCs, XPanels, IPCs) using a standard Ethernet connection.

Communication Settings: Xpanel

I/O Device Configuration

To create a new device, click Tools > I/O Device Editor… > click the + icon > click Ethernet under Connection Type > select CIMON CI-net (CIMON-PLC) for Device Type.

Image Modified

I/O Device Settings

 

Once the connection type, device name, and device type have been assigned, the I/O Device Editor window populates with the default settings for the selected communication protocol.

Image Modified

After selecting the correct Connection Type and Device Type, match the remaining settings to the target I/O device’s communication settings.

See the Communication Configuration section for more information.

Communication Settings: PLC

Communication Module

If using one of the following PLC modules to communicate with Xpanel, the card settings must be configured in CICON as shown below:

  • CM1 - EC01A

  • CM1 - EC10A

  • CM1 - EC10B

  • CM3 - SP01EET

  • BPnnMxxx - U

All communication parameters must match the settings chosen during the I/O device configuration in Canvas. Once the correct parameters have been entered, click Write while online with the PLC to update the communication parameters.

CPU Built-in Communication Port

If using a built-in CPU (PLC) ethernet port to communicate with Xpanel, the channel settings must be configured in CICON as shown below:

This connection option is available with the following models:

  • CM1 - XP1F

  • BPnnMxxx - S

  • PLC-S

    All communication parameters must match the settings chosen during the I/O device configuration in Canvas.

...