| XT04 | XT07 | XT08 | XT10 | XT12 | XT15 |
COM1 | RS-232C | RS-232C | RS-232C | RS-422/485 | RS-422/485 | RS-422/485 |
COM2 | RS-422/485 | RS-422/485 | RS-422/485 | RS-232C | RS-232C | RS-232C |
COM3 | - | - | - | RS-232C | RS-232C | RS-232C |
(2) Device-Specific Properties
Depending on the selected [Device Protocol], the available properties in the [PLC Type] tab change and a new tab unique to the device type may appear depending on the selection.
Item | Description | |
PLC Type | Allows the user to assign a specific model of PLC for the selected [Device Protocol]. This option is only enabled for the [CIMON CI-bus], [LSIS Cnet], [Mitsubishi MELSEC]. | |
ModbusRTU | When the [ModbusRTU] option is selected for the [Device Protocol], the following properties are revealed. | |
Swap 16 | Enable/Disable 16-bit data swaps. | |
Swap 32 | Enable/Disable 32-bit data swaps. | |
Swap String | Enable/Disable string swaps. | |
Melsec: Sum Check | Allows the user to enable or disable Sum Checks. |
(3) Station
Lastly, users can define the Station Name and Station Number of the selected Serial Device in the ‘Station’ tab.
...