Touch Condition Setting

Logical operations can be used to control touch features. When the result of a logical operation is True, the touch feature operates; otherwise it does not.

Action Delay Setting

Sets a delay option that executes by a set number of seconds. This option will be executed only when the button is pressed and held down for the assigned value. The value you can assign is from 1 (100msec100 msec) to 30 (30000msec30000 msec) seconds. Or you can input an analog tag name to specify delay time according to the assigned value.

On Delay

When touching the object for the set amount of time, the assigned action set in ‘Touch Down’ would run. If untouched before reaching the set amount of time, the object would not operate. ‘On Delay’ is usable for the ‘Touch Down’ action. The ‘Touch Up’ action operates with no relation to ‘On Delay’.

Off Delay

The assigned action would operate when releasing the object after the set amount of time (Delay time). ‘Off Delay’ is usable for the ‘Touch Down’ or ‘Touch Up’ action.

Double Touch

The assigned action would operate when touching the object and retouch in intervals. ‘Double Touch’ is usable for the ‘Touch Down’ or ‘Touch Up’ action.

Display Delay Status

When this option is selected, the ‘Delay’ status will be added in the ‘Shape Select’ window. While the ‘Delay setting’ is operating, the shape of the switch is changed into ‘Delay’ status so that you can view the delay time.

※ ‘Display Delay Status’ function is supported in XpanelDesigner 2.53 and above versions.

Visible

When the option is selected, enter the tag name in the input field to specify the tag for visible condition. When the visible condition is satisfied, the corresponding switch object will appear.

※ ‘Visible’ function is supported in XpanelDesigner 2.53 and above versions.

ON

The switch object appears when the assigned digital tag value is ON(1) or the analog tag value is bigger than 0.

OFF

The switch object disappears when the assigned digital tag value is OFF(0) or the analog tag value is 0.

Security

Sets a security level on the object. (1-10)

※ Please refer to the ‘Security’ manual for more information.

...

Item

Description

State Select

Select a state of the tag (OFF or ON) when the label is displayed.
If you have configured multiple states on the [Lamp Feature] tab, you can select a state in the range as shown below.

Bit Lamp

With Data Condition Conversion

Max 16 states (0 ~ 15)

At Each Bit Conversion

Max 5 states (0 ~ 4)

Word Lamp

With Data Condition Conversion

Max 256 states (0 ~ 255)

At Each Bit Conversion

Max 17 states (0 ~ 16)

 

 

 

 

Input Type

Direct Input

The operator manually enters the text to be displayed on the object. You can enter up to 30,000 characters.

String Table

Retrieve the string you have entered in the string table. You can set group and string No.

※ Please refer to the ‘String Editor’ manual for more information about the string table.

Font Set

Configure the manually entered text’s properties, such as font type, font size, alignment, and slant.

RTL

RTL (Right-to-Left) language means the character writing starts from the right of the text field and continues to the left. When the option is selected, the text will be displayed in a reversed direction.

This option is enabled when the label is directly entered in the input field. Use the ‘RTL’ setting in the ‘String Table’ function when you wish to display strings through the string table. The RTL setting of a label is applied at the Xpanel runtime.

※ ‘RTL’ option is supported in XpanelDesigner 2.53 and above versions.

Apply Label to All State

The current label setting will be applied to all states.

Apply Font to All state

The current font setting will be applied to all states.

...