Parity: Select the same parity (None, Even, Odd) as the Devicedevice.
Data Bits: Select the same data bit setting (5 Bits, 6 Bits, 7 Bits, 8 Bits) as the Devicedevice.
Stop Bit(s): Select the same stop bit setting (1 Bit or 2 Bit) as the Devicedevice.
RTS/CTS: Select the proper signal control type (OFF, ON, Control) for the Devicedevice.
Comm. Type: Select the same Comm. communication type (RS-232C or RS-422/485) as the Devicedevice.
Retry No.: Set the number of retries for sending a frame when communication fails.
...
Station Name: Enter the station name for the I/O Devicedevice.
Station Type: Select the Device device model or CPU which will be connected to the Xpanel.
Station Number: Set the station number. It must match the Device’s device’s station number.
Options:
16Bit Data Swap: This option swaps bytes for all word- or double-word-sized data. The following diagram shows an example of byte-swapping:
Almost all data types will be influenced by this option except INT8 / UINT8 / BCD8 / UBCD8.
32Bit Data Swap: This option swaps words of all double-word-sized data. The following diagram shows an example of word swapping:
Tag values with data types INT32 / UINT32 / BCD32 / UBDC32 / FLOAT will be influenced by this option.
String Data Swap: Swaps the upper and lower bytes of string word data.
Using CheckSum: Use a CheckSum in the communication protocol.
Comm. Error Message Pop Up: Use a pop-up message when a communication error occurs.
...
Station Name: Enter the station name for the I/O Devicedevice.
Station Type: Select the Device device model or CPU which will be connected to the Xpanel.
...
16Bit Data Swap: This option swaps bytes for all word- or double-word-sized data. The following diagram shows an example of byte-swapping:
Almost all data types will be influenced by this option except INT8 / UINT8 / BCD8 / UBCD8.
32Bit Data Swap: This option swaps words of all double-word-sized data. The following diagram shows an example of word swapping:
Tag values with data types INT32 / UINT32 / BCD32 / UBDC32 / FLOAT will be influenced by this option.
String Data Swap: Swaps the upper and lower bytes of string word data.
Comm. Error Message Pop Up: Use a Poppop-up message when a communication error occurs.
Fixed ATVXEL Socket Port: Use a fixed socket port for Xpanel.
...