For normal communication between Xpanel and PMAC, some I-variables should have the values described below.

I-variable

Set Value

Remark

I0

0 .. 15

The station number ‘0’ is the default value of PMAC. To set up the PMAC to communicate as station 1 to 15 on a multi-drop serial cable, first communicate with the board as station 0. Set I0 to specify the new station number. Also, set I1 to 3 to enable the station number addressing.

I1

3

CS handshake is not used; the software card address is required.

I3

2

Communication handshake style and code.

I4

0

Checksum disabled, serial errors reported immediately.

I6

1

Error reporting mode.

I9

0 or 2

0 (short form of the decimal) or 2 (short form of hexadecimal).

I63

1

Echo the <Control-X> character.

I64

1

Enable the internal response tag.

...

The following table shows the list of devices that can be referenced in the Xpanel database.

Symbol

Description

Address Range

Type

Access

I

Variable of fixed meaning for card setup

0-8191

Analog

R/W

P

Global variable for programming use

0-8191

Analog

R/W

M

Variable assigned to a memory location for user

0-8191

Analog

R/W

Q

Local variable for programming use

0-8191

Analog

R/W

DELTA TAU PMAC communication driver supports only the FLOAT data type.

...