This driver supports communication with a CIMON-PLC through the RS-232-C or RS-422A HMI Protocol. The following PLC modules (options) support this HMI Protocol.

  • CP/XP Series

  • BP Series

  • PLCS Series

  • MP Series

Communication Setup: Xpanel

Create a new device

So create a new device, select ‘Tools’ → ‘I/O Devices’ or click the (blue star) icon in tool-bar. The following picture shows the first step of creating a new device:

Image Added

I/O Device Name: Assign a device name. This name will be used in the tag configuration window of the database, accompanied by the ‘Station Name’.

Select a device type

After selecting the ‘OK’ button in the previous step, the ‘Serial Communication Configuration’ dialog box will appear as shown in following picture:

Image Added

In this window, select ‘CIMON-PLC HMI’ as the device type and configure the remaining serial communication parameters. Ensure that these parameters match with the PLC configuration.

Create a station

Move to the ‘Station’ tab of the ‘Serial Communication Configuration’ dialog box. In this dialog box, all connected PLC stations can be configured and registered to the Xpanel. Each field can be configured with the following rules.

Image Added

Station Name: Give a name to the PLC. This name will be used in the database window, accompanied by the ‘Device Name’.

Station Type: Choose the type connected PLC. Options include “CP/XP Series”, “BP Series“, “PLCS Series“, and “MP Series“.

Network ID: This field has no effect.

Station No: Specify a decimal number between 0 and 31.

16bits Data Swap: This field has no effect.

32bits Data Swap: This field has no effect.

Using Checksum: This field has no effect.

Comm. Error Message Pop Up: If this item is checked, Xpanel displays a communication error notification message for every Rx and Tx error. Otherwise (unchecked), Xpanel does not display the message for communication errors. Only when there is a data transmit error (writing a tag value to the station) will the notification message pop up. The message box will close automatically after 5 seconds.

Communication Setup: PLC

Communication Module

If one of the following special function modules is used for an Xpanel connection, the module properties should be configured in CICON as shown in the following picture.

  • CM1-SC01A or B

  • CM1-SC02A

  • BPnnMxxx-U or T

Image Added

The protocol item must be set to ‘HMI Protocol’. Ensure that the other communication parameters are matched with XpanelDesigne.

CPU Embedded Port

If the CPU embedded port is used to connect to an Xpanel, the PLC port parameters must be configured within CICON, as shown in the following picture. Note that the channel number and type of serial connection (232, 422, or 485) may vary depending on the specific CPU model.

Image Added

This type of communication port is supported by following models :

· CM1-CP4C or D or U

· BPnnMxxx-R or S

Supported PLC Memory Addresses

Area

Symbol

Analog tag

Digital Tag

Remark

External Input

X

X0000 – X5110

X0000 – X511F

 

External Output

Y

Y0000 – Y5110

Y0000 – Y511F

 

Internal Relay

M

M0000 - M9990

M0000 - M999F

 

Internal Relay

L

L0000 – L9990

L0000 – L999F

 

Latch Relay

K

K0000 – K9990

K0000 – K999F

 

Flags

F

F0000 – F1270

F0000 – F127F

Read Only

Timer Output

T

Not supported

T0000 – T4095

 

Timer PV

TC

TC0000 – TC4095

Not supported

 

Timer SV

TS

TS0000 – TS4095

Not supported

 

Counter Output

C

Not supported

C0000 – C4095

 

Counter PV

CC

CC0000 – CC4095

Not supported

 

Counter SV

CS

CS0000 – CS4095

Not supported

 

Data Memory

D

D00000 – D31999

Not supported

 

Wiring Diagrams

RS-232-C

CM1-SC01A,SC02A

CM2-BPnnMxx-T

Image Added

CM1-CP4C :

           Option Port

Image Added

CM2-BP16Mxx-R

Image Added

RS-422-A

CM1-SC01A,SC02A

 

Image Added

CM1-CP4C :

           Option Port

Image Added

CM2-BP16Mxx-S

Image Added

CM2-BPnnMxx-U

Image Added